| Rafter with Insulation Between and Under | ||||||
| Rafter Dimensions | ||||||
| Rafter Depth | mm | Rafter Width | mm | Rafter Centres | ||
| mm | Insulation % | 87.25 | % | Rafter % | ||
| 12.75 | % | |||||
| Building Elements | ||||||
| Element | Material | t(mm) | λ(W/mK) | λ(W/mK) | R(m²K/W) | Notes |
| External Surface resistance | Rse | NA | - | - | 0.04 | Fixed |
| Roof Covering | 1.0 | 1.0 | 0.01 | Material | ||
| Batten Cavity | - | - | 0.09 | Cavity | ||
| Rafter Cavity | - | - | 0.09 | Cavity | ||
| Between Insulation | 0.022 | 0.026 | 5.77 | Insulation | ||
| Rafter | As shown above | 200 | 0.13 | 0.13 | 1.54 | Timber |
| Bridge Modification | Mod for rafter thermal bridge | - | - | Modified R | 5.23 | Calculated |
| Under Insulation | 0.022 | 0.022 | 1.82 | Insulation | ||
| Internal board | 0.23 | 0.23 | 0.052 | Board | ||
| Finish | 0.6 | 0.6 | 0.005 | Finish | ||
| Surface resistance | Rsi | NA | - | - | 0.1 | Fixed |
| Additional R value | m²K/W | - | - | 0 | Extra | |
| Results | ||||||
| Thermal Bridge | Resistance through Rafter | 3.65 | m²K/W | |||
| Through Rafter | Total Resistance | 7.44 | m²K/W | |||
| Cold bridge U value | 0.274 | W/m²K | U value | 0.134 | W/m²K | |